SMLP5-5

Single-mode and Multimode Loss Test Kit with TRM® 2.0  Reporting Software

NOYES SMLP5-5 rugged loss test kit for testing and certifying fiber networks to industry standards. Backlight display works well in darker environments or direct sunlight. Interchangeable connector adapters provide access to common network interfaces and provide access for cleaning launch and receive ports.
OLS4 Quad Source is an integrated two-port LED (850 and 1300 nm) and LASER (1310 and 1550 nm) light source designed for performing insertion loss measurements on multimode or single-mode fiber optic links. Each port can transmit highly stabilized output (single or dual wavelength) ensuring accurate test results per current TIA/EIA requirements.  Equipped with industry standard 2 kHz test tone, the OLS4 from AFL is an ideal tool to pair with an optical fiber identifier (OFI-200D) for use in fiber identification.

OPM5 Optical Power Meter provides accurate measurements, reference storage for each calibrated wavelength, offers multiple test tone detection for fiber identification, and in unit data storage. The simple to use interface allows for easy separation of test results into files. In unit file management provides access to files and results for quick and easy retest of fibers and keeps cable/job results separated for fast customer report generation. Quickly transfer test results to PC via USB interface.  
 

Automatic Wavelength Identification significantly increases efficiency

Standard Wave ID feature automatically detects and sets the receive wavelength(s), preventing setup and measurement errors. It significantly increases efficiency and reduces technician errors—and saves testing time—by eliminating the need to test each wavelength individually.
 

Test Results Storage, Transfer, and Post Processing with TRM® 2.0 

OPM5 File Management system allows technicians to organize test results into multiple files.  Stored OPM results may be transferred to PC via USB port for viewing, analysis, and professional report generation using the included Windows® compatible TRM® 2.0 Basic Test Results Manager software.  TRM® 2.0 allows users to apply industry standards based rules to test results and create comprehensive certification reports complete with Pass/Fail results and calculated headroom.
 

50 and 62.5 µm Fiber Mandrels Included

Mandrels condition test cable for use in certifying both 50 and 62.5 µm fiber links for current and planned high bit rate applications including Gigabit Ethernet and 10 Gigabit Ethernet.  Mandrels apply to launch jumpers is seconds without tools and ensure loss measurements comply with TIA/EIA-568-B standard.


Encircled Flux Compliance

International standards bodies established Encircled Flux (EF) guidelines (TIA-568-14-B and IEC 61280-1-4) to improve measurement repeatability by reducing loss measurement variation to within a target range of ± 10%.

EF Mode Conditioners attach to the output of your multimode source ensuring the "conditioned output" meets Encircled Flux specifications.  Compliance requires matching the output fiber size to the network fiber under test. AFL offers both 50 µm and 62.5 µm EF Mode Conditioners.  See below for list of fiber and connector combinations available. 
 

Key Specifications

 

OLS4 Quad MM/SM Source

SM Wavelengths: 1310 and 1550 nm
SM Output Power 0 dBm
MM Wavelengths: 850 and 1300 nm
MM Output Power -20 dBm
Test Tones: 270 Hz, 330 Hz, 1 kHz, 2 kHz


OPM5 Optical Power Meter

Detector: Germanium
Calibrated Wavelengths: 850, 1300, 1310, 1490, 1550 nm
Measurement units: db, dBm, µW 

 

Ordering Information

 
Model number: SMLP5-5xx (xx = FC, SC, ST, or LC)
The SMLP5-5 combines one (1) OLS4 Quad MM/SM Source and one (1) OPM5 Power Meter.